Laser rangefinder of relatively eye-safe wavelength range
Dzyubenko, MI, Kolenov, IV, Pelipenko, VP, Dakhov, NF, Degtyarev, AV |
Organization: O.Ya. Usikov Institute for Radiophysics and Electronics of NASU V.N. Karazin Kharkiv National University Kharkiv National University of Radio Electronics E-mail: mid41@ukr.net |
https://doi.org/10.15407/rej2021.01.041 |
Language: ukranian |
Abstract: Subject and Purpose. The development and prototype making of a laser rangefinder operating in the 1.50…1.70 μm spectral region is reported. This wavelength region is attractive to both laser producers and laser users for, first of all, relative eye-safety of radiation. Methods and Methodology. The paraxial scheme of rangefinder construction is used, involving a software-controlled power supply of laser radiation with technical arrangements providing its adaptation to varying operating conditions. The alignment of the transceiver channels is provided with laser beam visualization methods. Results. A pulsed laser rangefinder operating at a 1.54 μm wavelength has been developed, a prototype has been made. The rangefinder essentially consists of the transmitting and receiving channels and the visual channel for targeting. The radiation source is a pulsed laser on ytterbium-erbium glass with semiconductor diode pumping and modulated Q-factor. The laser provides a 6 mJ power pulse of 25 ns duration and 5 mrad radiation divergence. A laser light spot of a required aperture is formed using a Galilean telescope system. For the photodetector of the reflected radiation, a pin-photodiode with a photosensitive area diagonal of 0.3 mm and a 2.5 ns time resolution is used. The echo signal processing module has been developed and performed, providing a high-precision registration of a time delay between the starting and reflected pulses. An effective method with the use of a charge-coupled device and an LCD monitor has been proposed and implemented for the alignment of all the three rangefinder channels. The rangefinder can operate in a single-pulse or repetitive-pulse mode with a probing pulse repetition rate of 1 Hz. Conclusion. A pulsed laser rangefinder operating in a relatively eye-safe spectrum region has been developed, a prototype has been made. The field tests have shown that the created rangefinder measures an object distance within 140…7 000 m with a measurement error no worse than 3 m. |
Keywords: channel alignment, diode pumping, imaging channel, transceiver channels, ytterbium-erbium laser |
Manuscript submitted 11.06.2020
Radiofiz. elektron. 2021, 26(1): 41-48
Full text (PDF)
-
1. Vasiliev, V.P., and Hinrikus, H.V. ed., 1995. Laser ranging. Moscow: Radio and communication Publ. (in Russsian). 2. Bondarenko, D.A., Karasik, V.E., Magdich, L.N., Pogonyshev, O.O., Sadovskiy, P.I., Semenkov, V.P., 2017. Compact erbium-glass diode pumping laser emitter with acousto-optic Q-switching. Herald of the Bauman Moscov State Tech. Univ. Instrum. Eng., 5, pp. 14-30. DOI: https://doi.org/10.18698/0236-3933-2017-5-14-30
3. Krylov, A.A., Buchenkov, B.A. and Uskov, A.V., 2018. Compact Q-switched Yb-Er laser with a pulse repetition rate of 10 Hz. Quantum Electron., 48(7), pp. 607-610. (in Russsian). DOI: https://doi.org/10.1070/QEL16617 4. Iskandarov, M.O., Nikitichev, A.A., Sverdlov, M.A., Ter-Martirosyan, A.L., 2015. Diode pumped solid state eye safe laser. Sci. Instrum., 25(3), pp. 124-126 (in Russsian). DOI: https://doi.org/10.18358/np-25-3-i124126 5. Rudnitskii, Y.P., Shachkin, L.V., Zalevskii, I.D., 2002. On the kinetics of nonradiative energy transfer in Yb-Er phosphate glass excited by a diode laser. Quantun Electron., 32(3), pp. 197-201 (in Russsian). DOI: https://doi.org/10.1070/QE2002v032n03ABEH002159 6. Stavrov, A.A., Pozdnykov, M.G., 2003. Pulse laser Rangefinders fo Optical Locating Systems. Doklady BGUIR, 1(2), pp. 59-65 (in Russsian). 7. Mierczyk, Z., 2000. ˮEye-safeˮ laser systems. Proc. SPIE, 4237, pp. 177-188. 8. Karasik, V.E. ed., 2012. Laser devices and methods of measuring range: textbook. Moscow: Publishing House of Moscow State Technical University named after N.E. Bauman (in Russsian). 9. Dzyubenko, M.I., Pelipenko, V.P., Kolenov, I.V., Dahov, N.F., 2019. Laser on erbie glass with diode pumping. In: Radiotehnika. Kharkov: NURE Publ. 199, pp. 104-109 (in Russsian). DOI: https://doi.org/10.30837/rt.2019.4.199.13 10. Dzyubenko, M.I., Kolenov, I.V., Pelipenko, V.P., Dahov, N.F., 2020. Pulse power supply of diode-pumped solid-state lasers. In: Radiotehnika. Kharkov: NURE Publ. 201, pp. 186-193 (in Russsian). DOI: https://doi.org/10.30837/rt.2020.2.201.18 11. Zheng, R. & Wu, G., 2012. Constant fraction discriminator in pulsed time-of-flight laser rangefinding. Front. Optoelectron., 5(2), pp. 182-186. DOI: 10.1007/s12200-012-0229-2. DOI: https://doi.org/10.1007/s12200-012-0229-2 12. Kilpelä, Ari, Ylitalo, Juha, Määttä, Kari, and Kostamovaara, Juha, 1998. Timing discriminator for pulsed time-of-flight laser rangefinding measurements. Rev. Sci. Instrum., 69(5), pp. 1978-1984. DOI: https://doi.org/10.1063/1.1148884 13. Kuvshinov, N.G., Nugin, A.V., Pronin, V.V., 2017. Alignment of the receiving channel of a pulsed laser rangefinder. J. Opt. Technol., 85(2), pp. 115-118. DOI: https://doi.org/10.1364/JOT.85.000115 14. Beloyvan, P.A., Nazarov, V.N., Latiev, S.M., Sologubova, I.S., Pashkevich, M.L., 2016. Automatic adjustment of parallelism of theenergy axis of the transmission channel and the axis of the receiving channel of a laser rangefinder. Mod. Problems Sci. Educ., 2 (pt. 2) (in Russsian). Available from: http://www.science-education.ru/ru/article/view?id=22779 15. Podkatilin, A.N., Chistyakov, A.Yu., 2014. Apparatus for inspecting, adjusting and converging optical axes of channels of multichannel devices and broadband radiator in visible and infrared regions. Russian Federation. Pat. 2511204 (in Russsian). 16. Vilner, V., Volobuev, V., Larjushin, A., Ryabokul, A., 2013. Reliability of measurements of a pulsed laser range finder. Photonics, 3, pp. 127-136 (in Russsian).